PRODUCT DETAILS

  • Industrial-UPS1
  • Industrial-UPS2
  • Industrial-UPS3
  • Industrial-UPS4
  • Industrial-UPS5

Customizable 50KW 200KW 500KW Low Frequency UPS Three-Phase Input/Output Industrial Grade Uninterruptible Power Supply

Short Description:

The system is designed with an online double-conversion topology, which completely eliminates various interferences from the power grid, making the UPS output a pure sine wave power supply with stable frequency and voltage, noise filtering, no interference from power grid fluctuations, and low distortion.

Product Category:

PRODUCT DETAILS

Features

  1. Design Concept: High Reliability

The UPS’s main input power and bypass power supply are separable, providing dual power inputs. This allows for two separate mains power lines to be connected to the UPS, improving output power reliability. The double-conversion online topology design provides pure, sinusoidal power with frequency tracking, phase locking, voltage regulation, and noise filtering, making it immune to grid fluctuations and providing comprehensive protection for user equipment.

  1. High Battery Optimization

Adopting Intelligent Battery Management (ABM) technology, the UPS extends battery life and reduces maintenance. Advanced constant current automatic charging technology maximizes battery life, shortens charging time, and extends battery life.

  1. Strong Redundancy/Capacity Parallel Capability

Up to eight units can be paralleled by inserting an optional parallel module, increasing system reliability. The system offers high scalability and easy parallelization. Parallel operation with a non-fixed master-slave relationship: Among several UPS units connected in parallel, the first one to power on is the master UPS, and the others are slaves. The master and slave UPSs can be interchanged. If one UPS fails, it automatically shuts down, and the remaining UPSs then provide power to the load.

  1. Energy-saving and Environmentally Friendly Design

The detachable design facilitates maintenance and conserves resources. Intelligent fan speed control intelligently turns the fan on/off and adjusts speed based on the load of each UPS power component, ambient temperature, and actual temperature rise. This provides excellent heat dissipation and high energy efficiency. A non-circulating current control circuit ensures excellent power conservation. Green rectification and inverter technologies are employed to provide users with clean energy.
Technical Parameters

MODEL BT8010H-33 BT8015H-33 BT8020H-33 BT8030H-33 BT8040H-33 BT8060H-33 BT8080H-33 BT81000H-33 BT8120H-33 BT8160H-33 BT8200H-33
CAPACITY 10KVA/8 KW 15KVA/12KW 20KVA/16KW 30KVA/24KW 40KVA/24KW 60KVA/48KW 80KVA/64KW 100KVA/80KW 120KVA/96KW 160KVA/128KW 200KVA/160KW
INPUT
Nominal Voltage 3 x 380VAC/400VAC/415VAC (3Ph + N)
Acceptable Voltage Range 165VAC ~ 280VAC (Ph-N); 285VAC ~ 485VAC (Ph-Ph)
Frequency 50/60 Hz ± 10 %
INVERTER
Nominal Voltage 3 x 380VAC/400VAC/415VAC (3Ph + N)
Precision Stationary: ±1%; Transitory:  ±5% (load variations 100-0-100%)
Frequency 50/60 Hz syn chronised ±1 % With mains absent ±0.1 Hz
Max. Synchronization Speed ±1 Hz/s
Waveform Pure Sinewave
Total Harmonic Distortion <2% (Linear Load); <5% (Non-linear Load)
(THDV)
Phase Displacement 120º ±1% (balanced load); 120º ±2% (imbalances 50% of the load)
Dynamic Recovery Time 3 cycles at 90 % of the static value
Admissible Overload 110% for 10min; 150% for 60sec; >160% for 200ms
Admissible Crest Factor 3:01
Admissible Power Factor 0.6~1 (inductive or capacitive)
Imbalance Output Voltage <1%
@ 100% Unbalanced Load
Current Limit High overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit
STATIC BYPASS
Type Solid state
Voltage 176VAC ~ 264VAC (Ph-N); 304VAC ~ 456VAC (Ph-Ph)
Frequency 50/60 Hz ± 10 %
Activation Criterion Microprocessor control
Transfer Time Zero
Admissible Overload 150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to Bypass Immediate, for overloads above 160%
Retransfer Automatic after alarm clear
MAINTENANCE BYPASS
Type Without interruption
Voltage Same as the bypass input
Frequency Same as the bypass input
Overall Efficiency Line Mode 89% 90% 91% 92%
Battery Mode 90% 91% 92% 93%
BATTERY & CHARGER
Battery Type and Numbers 12VDC x 32 pcs (29~32 pcs adjustable)
Nominal Battery Voltage 384 VDC (Based on 32pcs batteries)
Charging Method CC/CV
Precision ±1%
Charging Current Default 10A, *Maximum=Capacity (KW)/ Battery Voltage(real-time) Default 10A; Maximum 40A; 5A@ full load
Charging Voltage 432 VDC (Based on 32pcs batteries)
PHYSICAL
Dimensions, D x W x H (mm) 656 x 405 x 817 656 x 405 x 941 821 x 432 x 1159 975 x 554 x 1286 975 x 635 x1326 1051 x 705 x 1646
Net Weight (Kgs) 118 120 145 193 278 365 471 573 650 735 790

Applications:
Industrial process (manufacturing and control system, industrial machinery, instrument and measurement, process monitoring and control, security and transport systems….)
Infrastructures (hospital, airport, semiconductor, water treatment, power plant, metallurgy)
Energy industry (gas and oil, petrochemical, mining)
Military application

PRODUCT CONSULTATION

Contact Form Demo