Rack Power Supplies

11/16/2022

The rack-mounted power supply is a power supply device mainly used in the integrated centralized power supply of the security system. It is an inevitable product for the standardized management and centralized management of the security system. Can output sine wave, zero conversion time.
Scope of application
Adapt to China’s power grid environment: office, computer room, industrial environment, etc.
The rack-mounted power supply introduced here is one of many power supplies. It is mainly used in the power supply equipment of the integrated centralized power supply of the security system. It is an inevitable product of the standardized management and centralized management of the security system. The traditional power supply method is to obtain 220V power supply or lay a 220V power supply from the computer room to each camera image acquisition point, and then step down through a small transformer to 24V or 12V power supply used by the camera. This approach must be that the power supply equipment is scattered and the power transformer is exposed. Outdoor, harsh environment, sun and rain! The service life of the equipment will inevitably be affected, and the maintenance cost will inevitably increase. The centralized power supply method can make the equipment have a better environment and higher stability in the equipment room. It will definitely be the development direction of the security integrated system. Power supply to important equipment Adopting dual backup power supply and adding UPS system, it will be an inevitable requirement for many occasions to collect clear images in the event of a power outage; a series of rack-mounted security power supplies launched in response to market demand just solves the current market gap.
Performance characteristics
Sine wave output
No matter in mains mode or battery mode, it can output low-distortion sine wave power supply to provide the best power supply protection for user’s load equipment.
Zero conversion time
When the mains power is cut off or restored, the UPS switches between the mains mode and the battery mode without switching time, which effectively ensures the reliability of the load operation.
Detection function
Rack UPS 1K~3K(S) has zero fire wire reverse connection detection function. , to avoid the reverse connection of the UPS mains input neutral wire.
Bypass output
In order to prevent the user from letting the UPS work in BYPASS MODE and not turning it on, causing interruption of the mains power, both the UPS and the equipment are shut down abnormally. Rack UPS 1K~3K(S) input normal mains power, no bypass output by default. It must be turned on to have normal inverter output. But you can change the configuration to “listed power with bypass output” through the WinPower2000 software on the website.

TVSS function
That is TRANSIENT VOLTAGE SURGE SUPPRESS surge voltage protection function. It is used for FAX, TELEPHONE, MODEM, network and other conversion protection functions on Rack UPS.
input power factor correction
Rack UPS has input power factor correction function. Under full load, the input power factor can reach more than 0.95, so that the user’s power grid environment will not be polluted.
DC start
In the state of mains power failure, if you need to use the Rack UPS to start the computer or other load equipment, the Rack UPS can directly start the DC power with the battery, which makes the use of the Rack UPS more convenient and reliable.
Bypass protection
The bypass power supply function greatly enhances the emergency handling capability of the Rack UPS. At the same time, when the user’s load equipment has special requirements for the power supply, such as the voltage cannot be too high, the Rack UPS provides the bypass power supply voltage over-voltage protection, so that the user’s load equipment can be protected from excessive voltage. danger of high pressure.
Auto start function
When the utility power is abnormal, the Rack UPS will shut down when it enters the battery mode to supply power until it is cut off. When the utility power returns to normal, the Rack UPS will automatically start up again to restore the normal power supply, without the need for users to turn it on one by one.
long-term power supply
Rack UPS provides a comprehensive long-term machine for users to choose. Equipped with a suitable battery pack, the user can discharge for about 8 hours to meet the requirements of different grid environments.
Self-check function
Rack UPS can simulate a power failure and enter the battery mode to supply power. This function can be executed at any time through the self-check button on the panel, or it can be performed on a regular or irregular basis with monitoring software.
Strong anti-interference
For electromagnetic interference and radio frequency interference, Rack UPS is designed in accordance with international standards EN50091-2 and IEC61000-4 series standards, which effectively improves the safety and reliability of UPS use.
Compatible with generator
The wide input voltage and frequency range enables the Rack UPS to be used with major brand generators, extending the service time, and at the same time effectively removing the bad power generated by the generator, providing pure, safe and stable power for the load.
Inductive load can be connected
Rack UPS can be connected to inductive loads (pf=0.8). If customers have other special needs, they can contact Santak directly.
Monitoring software
In order to make the user’s management of UPS more convenient and effective, WinPower2000 network version monitoring software can be downloaded from the company’s website for free to realize intelligent management.
Equipped with smart slot
The Rack UPS is equipped with an Intelligent Slot. Users can purchase an AS400 card to provide IBM AS400 standard communication signals. Users can use the AS400 interface for Remote Display, including audible alarm and light display. Or purchase a WebPower intelligent monitoring card for global management through the Internet, or through SNMP network management to achieve centralized monitoring and remote monitoring and other functions.
Standard battery pack
The Rack UPS is equipped with a standard battery pack of the same size as the host (for customers to choose). In addition to requiring one set of standard battery packs for C2KR, C3KR, and C6KR standard machines, C1KRS and C6KRS long-term machines are also required to be equipped with more than 2 sets of standard battery packs, and C2KRS and C3KRS long-term machines are required to be equipped with more than 3 sets of standard battery packs. The batteries in the standard battery pack are all high-quality original Panasonic batteries, which ensure the safety and reliability of the UPS with good battery quality.